Specification:
Bus Interface | PCI-Express 3.0 x16 |
Number of Channel / Port | 3* 2280 M.2 NVMe port (Dedicated PCIe 3.0 x4 per port) |
Data Transfer Rates | 8GT per lane / 8Gbps per lane |
Number of Devices | 3x M.2 NVMe SSD |
16x SAS/SATA Drive | |
Form Factor | Full-Height |
Dimensions | 5.97" x 2.68" x 0.06" |
Weight | 0.77 lbs. |
Operating System Support | Windows 10, Windows Server 2012 R2 or later |
Linux Kernel 3.3 or later | |
macOS 10.13 or later | |
Cooling Fan | Aluminum casing with single 50x50mm fan blower |
RAID Mode Support | Single, RAID 0, 1, 5* (For Mac support, please contact Sales) |
TRIM RAID Support | Windows: Single, RAID 0, 1 |
Linux: Single, RAID 0, 1 | |
Storage Mode - NVMe | Bootable & Data RAID |
RAID Management Suites | Browser-Based management tool |
CLI (Command Line Interface - scriptable configuration tool) | |
API package | |
SMTP Email Alert Notification | Yes |
Storage Health Inspector | Yes |
NVMe SMART status | Yes |
Global Hot Spare Disk support | Yes |
Automatic and configurable RAID Rebuilding Priority | Yes |
Auto resume incomplete rebuilding after reboot | Yes |
Single-RAID or Multi-RAID Arrays per Controller | Yes |
Cross-Sync RAID Solution Across Controllers | Yes |
SAS Port | 16 internal SAS 12Gb/SATA 6Gb Ports |
(4* SFF-8643 Connector) | |
RAID Level Support | 0, 1, 5, 6, 1/0**, 50 and JBOD / Non-RAID Mode |
SAS Enclosure Management Interface | SGPIO |
Storage Health Inspector (SHI) | Yes |
Redundant RAID Configurations | Yes |
Multiple RAID Partitions supported | Up to 4 |
Storage Configurations | Direct Attached |
Online Array Roaming | Yes |
Online RAID Level Migration (ORLM) | Yes |
Online Capacity Expansion (OCE) | Yes |
RAID Quick Initialization for fast array setup | Yes |
Drive hot-plug support | Yes |
Global Hot Spare Disk support | Yes |
Automatic and configurable RAID Rebuilding Priority | Yes |
Auto resume incomplete Rebuilding after power on or reboot system | Yes |
Disk Format compatible | 512, 512e, 4Kn |
Larger than 2 TB Drive and RAID Array support | Yes |
Spin down Massive Arrays of Idle Disks support | Yes |
Native Command Queuing | Yes |
SAS TCQ | Yes |
Disk media scan and repair | Yes |
Device Error Recovery support | Yes |
Automatic remap and fix drive bad block for RAID array | Redundant RAID Levels (RAID 1, 5, 6, 1/0, 50) |
Staggered Drive Spin Up | Yes (Spin up 4 disk every 2s) |
Write Back and Write Through | Yes |
Contact: Danny Tean
Phone: +86 13631662771
Tel: 86 13631662771
Add: Rm201, 2F, building A, Optics valley free trade harbour, No.99 High-Tech 6th Rd, Optics Valley, Wuhan, China 430205
Rm201, 2F, building A, Optics valley free trade harbour, No.99 High-Tech 6th Rd, Optics Valley, Wuhan, China 430205
+86 13631662771